Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 25.672
Filter
1.
Water Sci Technol ; 89(7): 1630-1646, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38619894

ABSTRACT

Due to the colloidal stability, the high compressibility and the high hydration of extracellular polymeric substances (EPS), it is difficult to efficiently dehydrate sludge. In order to enhance sludge dewatering, the process of ultrasonic (US) cracking, chitosan (CTS) re-flocculation and sludge-based biochar (SBB) skeleton adsorption of water-holding substances to regulate sludge dewaterability was proposed. Based on the response surface method, the prediction model of the specific resistance to filtration (SRF) and sludge cake moisture content (MC) was established. The US cracking time and the dosage of CTS and SBB were optimized. The results showed that the optimal parameters of the three were 5.08 s, 10.1 mg/g dry solids (DS) and 0.477 g/g DS, respectively. Meantime, the SRF and MC were 5.4125 × 1011 m/kg and 76.8123%, which significantly improved the sludge dewaterability. According to the variance analysis, it is found that the fitting degree of SRF and MC model is good, which also confirms that there is significant interaction and synergy between US, CTS and SBB, and the contribution of CTS and SBB is greater. Moreover, the process significantly improves the sludge's calorific value and makes its combustion more durable.


Subject(s)
Chitosan , Sewage , Ultrasonics , Charcoal , Filtration , Water , Waste Disposal, Fluid/methods
2.
BMC Oral Health ; 24(1): 417, 2024 Apr 05.
Article in English | MEDLINE | ID: mdl-38580933

ABSTRACT

BACKGROUND: Many instruments used in dentistry are rotary, such as handpieces, water syringes, and ultrasonic scalers that produce aerosols. The spray created by these instruments can carry, in addition to water, droplets of saliva, blood, and microorganisms, which can pose a risk of infections for healthcare professionals and patients. Due to the COVID-19 pandemic, this gained attention. OBJECTIVE: The aim was to carry out a systematic review of the evidence of the scope of the aerosol produced by ultrasonic scaler in environmental contamination and the influence of the use of intraoral suction reduction devices. DESIGN: Scientific literature was searched until June 19, 2021 in 6 databases: Pubmed, EMBASE, Web of science, Scopus, Virtual Health Library and Cochrane Library, without restrictions on language or publication date. Studies that evaluated the range of the aerosol produced by ultrasonic scaler during scaling/prophylaxis and the control of environmental contamination generated by it with the use of low (LVE) and high (HVE) volume evacuation systems were included. RESULTS: Of the 1893 potentially relevant articles, 5 of which were randomized controlled trials (RCTs). The meta-analysis of 3 RCTs showed that, even at different distances from the patient's oral cavity, there was a significant increase in airborne bacteria in the dental environment with the use of ultrasonic scaler. In contrast, when meta-analysis compared the use of HVE with LVE, there was no significant difference (P = 0.40/CI -0.71[-2.37, 0.95]) for aerosol produced in the environment. CONCLUSIONS: There is an increase in the concentration of bioaerosol in the dental environment during the use of ultrasonic scaler in scaling/prophylaxis, reaching up to 2 m away from the patient's mouth and the use of LVE, HVE or a combination of different devices, can be effective in reducing air contamination in the dental environment, with no important difference between different types of suction devices.


Subject(s)
Ultrasonic Therapy , Humans , Ultrasonics , Respiratory Aerosols and Droplets , Aerosols/adverse effects , Water , Dental Scaling
3.
Med Eng Phys ; 126: 104129, 2024 04.
Article in English | MEDLINE | ID: mdl-38621834

ABSTRACT

3D printed Poly Lactic Acid (PLA) bone plates exhibit limited three-point bending strength, restricting their viability in biomedical applications. The application of polydopamine (PDM) enhances the three-point bending strength by undergoing covalent interactions with PLA molecular structure. However, the heavy nature of PDM particles leads to settling at the container base at higher coating solution concentrations. This study investigates the impact of ultrasonic-assisted coating parameters on the three-point bending strength. Utilizing Response Surface Methodology (RSM) for statistical modeling, the study examines the influence of ultrasonic vibration power (UP), coating solution concentration (CC), and submersion time (TIME). RSM optimization recommended 100 % UP, 6 mg/ml CC, and 150 min TIME, resulting in maximum three-point bending strength of 83.295 MPa. Microscopic images from the comparative analysis revealed non-uniform coating deposition with mean thickness of 6.153 µm under normal coating. In contrast, ultrasonic-assisted coating promoted uniform deposition with mean thickness of 18.05 µm. The results demonstrate that ultrasonic-assisted coating induces PDM particle collision, preventing settling at the container base, and enhances three-point bending strength by 7.27 % to 23.24 % compared to the normal coating condition. This study emphasizes on the potential of ultrasonic-assisted coating to overcome the limitations of direct immersion coating technique.


Subject(s)
Bone Plates , Ultrasonics , Polyesters/chemistry , Ultrasonic Waves , Printing, Three-Dimensional
4.
BMJ Open ; 14(4): e082024, 2024 Apr 18.
Article in English | MEDLINE | ID: mdl-38637127

ABSTRACT

BACKGROUND: Postoperative pancreatic fistula (POPF) remains the most common and serious complication after distal pancreatectomy. Many attempts at lowering fistula rates have led to unrewarding insignificant results as still up to 30% of the patients suffer from clinically relevant POPF. Therefore, the development of new innovative methods and procedures is still a cornerstone of current surgical research.The cavitron ultrasonic surgical aspirator (CUSA) device is a well-known ultrasound-based parenchyma transection method, often used in liver and neurosurgery which has not yet been thoroughly investigated in pancreatic surgery, but the first results seem very promising. METHODS: The CUSA-1 trial is a randomised controlled pilot trial with two parallel study groups. This single-centre trial is assessor and patient blinded. A total of 60 patients with an indication for open distal pancreatectomy will be intraoperatively randomised after informed consent. The patients will be randomly assigned to either the control group with conventional pancreas transection (scalpel or stapler) or the experimental group, with transection using the CUSA device. The primary safety endpoint of this trial will be postoperative complications ≥grade 3 according to the Clavien-Dindo classification. The primary endpoint to investigate the effect will be the rate of POPF within 30 days postoperatively according to the ISGPS definition. Further perioperative outcomes, including postpancreatectomy haemorrhage, length of hospital stay and mortality will be analysed as secondary endpoints. DISCUSSION: Based on the available literature, CUSA may have a beneficial effect on POPF occurrence after distal pancreatectomy. The rationale of the CUSA-1 pilot trial is to investigate the safety and feasibility of the CUSA device in elective open distal pancreatectomy compared with conventional dissection methods and gather the first data on the effect on POPF occurrence. This data will lay the groundwork for a future confirmatory multicentre randomised controlled trial. ETHICS AND DISSEMINATION: The CUSA-1 trial protocol was approved by the ethics committee of the University of Heidelberg (No. S-098/2022). Results will be published in an international peer-reviewed journal and summaries will be provided in lay language to study participants and their relatives. TRIAL REGISTRATION NUMBER: DRKS00027474.


Subject(s)
Pancreatectomy , Ultrasonics , Humans , Pancreatectomy/adverse effects , Pancreatectomy/methods , Pilot Projects , Pancreas/diagnostic imaging , Pancreas/surgery , Pancreatic Fistula/etiology , Pancreatic Fistula/prevention & control , Pancreatic Fistula/epidemiology , Postoperative Complications/epidemiology , Randomized Controlled Trials as Topic , Multicenter Studies as Topic
5.
J Contemp Dent Pract ; 25(2): 180-185, 2024 Feb 01.
Article in English | MEDLINE | ID: mdl-38514417

ABSTRACT

AIM: To evaluate the intensity of postendodontic pain (PEP) using final irrigation with side-vented needle (SV), EndoActivator (EA), and Ultra X (UX) in single-visit endodontics (SVE) with F-One rotary files. MATERIALS AND METHODS: A total 150 patients indicated for endodontic treatment were selected. Single-visit endodontics treatment was performed under local anesthesia. For the final irrigation protocol, they were divided into three groups: group I (SV), group II (EA), and group III (UX). The severity of PEP was assessed using visual analogue scale (VAS) score after 6, 12, 24, and 48 hours. Analgesics taken by patients, for pain, were also recorded. Finally, the data were tabulated and statistically analyzed using SPSS 20.0 software at a level of significance being 0.05. RESULTS: Postendodontic pain was less in group III (UX) and group II (EA) compared with group I (SV) at 6 and 12 hours, which is statistically significant (p < 0.05). There was no statistically significant difference found after 24 hours and 48 hours. CONCLUSION: The intensity of PEP was minimum in patients treated with EndoActivator and ultrasonic along with single rotary file systems. The incidence of analgesic intake was similar in all three groups. How to cite this article: Kathiria NV, Attur K, Bagda KM, et al. Postendodontic Pain Using Single File System with Different Irrigation Protocols in Single-visit Root Canal Treatment: A Randomized Control Trial. J Contemp Dent Pract 2024;25(2):180-185.


Subject(s)
Dental Pulp Cavity , Root Canal Preparation , Humans , Pain, Postoperative , Randomized Controlled Trials as Topic , Root Canal Preparation/methods , Root Canal Therapy/methods , Ultrasonics , Double-Blind Method
6.
Front Endocrinol (Lausanne) ; 15: 1344666, 2024.
Article in English | MEDLINE | ID: mdl-38544693

ABSTRACT

Background: To explore the predictive value of placental features in early pregnancy for gestational diabetes mellitus (GDM) using deep and radiomics-based machine learning (ML) applied to ultrasound imaging (USI), and to develop a nomogram in conjunction with clinical features. Methods: This retrospective multicenter study included 415 pregnant women at 11-13 weeks of gestation from two institutions: the discovery group from center 1 (n=305, control group n=166, GDM group n=139), and the independent validation cohort (n=110, control group n=57, GDM group n=53) from center 2. The 2D USI underwent pre-processed involving normalization and resampling. Subsequently, the study performed screening of radiomics features with Person correlation and mutual information methods. An RBF-SVM model based on radiomics features was constructed using the five-fold cross-validation method. Resnet-50 as the backbone network was employed to learn the region of interest and constructed a deep convolutional neural network (DLCNN) from scratch learning. Clinical variables were screened using one-way logistic regression, with P<0.05 being the threshold for statistical significance, and included in the construction of the clinical model. Nomogram was built based on ML model, DLCNN and clinical models. The performance of nomogram was assessed by calibration curves, area under the receiver operating characteristic curve (AUC) and decision curve analysis (DCA). Results: The AUCs for the ML model in the discovery cohort and independent validation cohort were 0.91 (0.88-0.94) and 0.86 (0.79-0.93), respectively. And 0.65 (0.59-0.71), 0.69 (0.59-0.79) for the DLCNN, 0.66 (0.59-0.72), 0.66 (0.55-0.76) for the clinical model, respectively. The nomogram exhibited the highest performance with AUCs of 0.93 (0.90-0.95) and 0.88 (0.81-0.94) The receiver operating characteristic curve (ROC) proved the superiority of the nomogram of clinical utility, and calibration curve showed the goodness of fit of the model. The DCA curve indicated that the nomogram outperformed other models in terms of net patient benefit. Conclusions: The study emphasized the intrinsic relationship between early pregnancy placental USI and the development of GDM. The use of nomogram holds potential for clinical applications in predicting the development of GDM.


Subject(s)
Artificial Intelligence , Diabetes, Gestational , Pregnancy , Female , Humans , Ultrasonics , Diabetes, Gestational/diagnosis , Placenta/diagnostic imaging , Neural Networks, Computer
7.
Sci Rep ; 14(1): 5368, 2024 03 04.
Article in English | MEDLINE | ID: mdl-38438434

ABSTRACT

Ultrasonic irrigation during root canal treatment can enhance biofilm disruption. The challenge is to improve the fluid flow so that the irrigant reaches areas inaccessible to hand instrumentation. The aim of this study is to experimentally investigate how the flow field and hydrodynamic forces induced by ultrasonic irrigation are influenced by the ultrasound power and file insertion depth. A root canal phantom was 3D printed and used as a mold for the fabrication of a PDMS channel. An ultrasonic instrument with a #15K-file provided the irrigation. The flow field was studied by means of Particle Image Velocimetry (PIV). The time averaged velocity and shear stress distributions were found to vary significantly with ultrasound power. Their maximum values increase sharply for low powers and up to a critical power level. At and above this setting, the flow pattern changes, from the high velocity and shear stress region confined in the vicinity of the tip, to one covering the whole root canal domain. Exceeding this threshold also induces a moderate increase in the maximum velocities and shear stresses. The insertion depth was found to have a smaller effect on the measured velocity and shear stresses. Due to the oscillating nature of the flow, instantaneous maximum velocities and shear stresses can reach much higher values than the mean, especially for high powers. Ultrasonic irrigation will benefit from using a higher power setting as this does produce greater shear stresses near the walls of the root canal leading to the potential for increased biofilm removal.


Subject(s)
Dental Pulp Cavity , Ultrasonics , Ultrasonography , Phantoms, Imaging , Biofilms
8.
Braz Dent J ; 35: e245611, 2024.
Article in English | MEDLINE | ID: mdl-38537014

ABSTRACT

This study evaluated the correlation between root canal curvature and the effects of ultrasonic irrigation in the following parameters: volume of uncontrolled dentin removal (UDRVol), maximum depth of dentin defects, removal of accumulated hard tissue debris (AHTD), and canal transportation in prepared curved root canals. Twenty-four human permanent mandibular molars were divided into two groups according to root canal curvature: moderate curvature (MC: mean 25°); and severe curvature (SC: mean 48°). The specimens were scanned using an X-ray microcomputed scanner (Skyscan 1172) before and after cleaning and shaping and after the final irrigation protocol with ultrasonic irrigation. There was a moderate correlation between the degree of root canal curvature and the volume of remaining AHTD (p<0.05) and between the degree of root canal curvature and maximum depth of defects due to uncontrolled removal of dentin (p<0.05). The teeth in the SC group had a greater maximum depth of defects on the dentin wall in the apical third than the teeth in the MC group (p <0.05). Both groups had a significant reduction of AHTD in all canal thirds, but the amount of remaining AHTD in the middle and apical thirds and the whole canal was significantly greater in the SC than in the MC group (p <0.05). Canal transportation was not influenced by the canal curvature in all thirds (p >0.05). This study concluded that root canal curvature affects significantly the uncontrolled removal of dentin and remaining AHTD volume after the final irrigation protocol with ultrasonic irrigation.


Subject(s)
Dental Pulp Cavity , Root Canal Preparation , Humans , Root Canal Preparation/methods , Ultrasonics , Root Canal Irrigants , Therapeutic Irrigation/methods , X-Ray Microtomography , Dentin
9.
Talanta ; 273: 125879, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38490022

ABSTRACT

In order to improve the living standards of diabetes patients and reduce the negative health effects of this disease, the medical community has been actively searching for more effective treatments. In recent years, an artificial pancreas has emerged as an important approach to managing diabetes. Despite these recent advances, meeting the requirements for miniaturized size, accurate sensing and large-volume pumping capability remains a great challenge. Here, we present a novel miniaturized artificial pancreas based on a long microtube sensor integrated with an ultrasonic pump. Our device meets the requirements of achieving both accurate sensing and high pumping capacity. The artificial pancreas is constructed based on a long microtube that is low cost, painless and simple to operate, where the exterior of the microtube is fabricated as a glucose sensor for detecting diabetes and the interior of the microtube is used as a channel for delivering insulin through an ultrasonic pump. This work successfully achieved closed-loop control of blood glucose and treatment of diabetes in rats. It is expected that this work can open up new methodologies for the development of microsystems, and advance the management approach for diabetes patients.


Subject(s)
Diabetes Mellitus, Type 1 , Pancreas, Artificial , Wearable Electronic Devices , Humans , Animals , Rats , Hypoglycemic Agents/therapeutic use , Diabetes Mellitus, Type 1/drug therapy , Ultrasonics , Insulin , Blood Glucose
10.
Ultrasonics ; 139: 107299, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38508083

ABSTRACT

Dermal collagen is the most abundant component of human skin and has a network structure that regulates the mechanical properties of the skin. Therefore, non-invasive characterization of the collagen network would be beneficial for the evaluation of skin conditions. The microscopic substructures of the network, which are individual bundles and fibers, have been optically investigated. However, the macroscopic structure of the collagen network has not been assessed. To evaluate the dermal collagen network, we developed two new indicators, volume filling factor (VFF) and collagen fiber texture (CFT), to analyze three-dimensional echo intensity maps of high-frequency ultrasonic microscopy. By identifying the difference in the elastic modulus components of the dermal layer of facial skin, the density and texture of the collagen network were characterized using VFF and CFT, respectively. These new indicators revealed that the density decreased and the texture became fine with facial age. This study demonstrates that ultrasonic microscopy is useful for investigating skin conditions, paving the way for diagnostic applications in dermatology and aesthetic medicine.


Subject(s)
Microscopy , Ultrasonics , Humans , Cheek/diagnostic imaging , Skin/diagnostic imaging , Collagen
11.
Int J Pharm ; 655: 124049, 2024 Apr 25.
Article in English | MEDLINE | ID: mdl-38537921

ABSTRACT

In in-process quality monitoring for Continuous Manufacturing (CM) and Critical Quality Attributes (CQA) assessment for Real-time Release (RTR) testing, ultrasonic characterization is a critical technology for its direct, non-invasive, rapid, and cost-effective nature. In quality evaluation with ultrasound, relating a pharmaceutical tablet's ultrasonic response to its defect state and quality parameters is essential. However, ultrasonic CQA characterization requires a robust mathematical model, which cannot be obtained with traditional first principles-based modeling approaches. Machine Learning (ML) using experimental data is emerging as a critical analytical tool for overcoming such modeling challenges. In this work, a novel Deep Neural Network-based ML-driven Non-Destructive Evaluation (ML-NDE) modeling framework is developed, and its effectiveness for extracting and predicting three CQAs, namely defect states, compression force levels, and amounts of disintegrant, is demonstrated. Using a robotic tablet handling experimental rig, each attribute's distinct waveform dataset was acquired and utilized for training, validating, and testing the respective ML models. This study details an advanced algorithmic quality assessment framework for pharmaceutical CM in which automated RTR testing is expected to be critical in developing cost-effective in-process real-time monitoring systems. The presented ML-NDE approach has demonstrated its effectiveness through evaluations with separate (unused) test datasets.


Subject(s)
Technology, Pharmaceutical , Ultrasonics , Mechanical Phenomena , Pressure , Tablets
12.
Ultrasonics ; 139: 107274, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38428161

ABSTRACT

Numerous quantitative ultrasound imaging techniques have demonstrated superior monitoring performance for thermal ablation when compared to conventional ultrasonic B-mode imaging. However, the absence of comparative studies involving various quantitative ultrasound imaging techniques hinders further clinical exploration. In this study, we simultaneously reconstructed ultrasonic Nakagami imaging, ultrasonic horizontally normalized Shannon entropy (hNSE) imaging, and ultrasonic differential attenuation coefficient intercept (DACI) imaging from ultrasound backscattered envelope data collected during high-intensity focused ultrasound ablation treatment. We comprehensively investigated their performance differences through qualitative and quantitative analyses, including the calculation of contrast-to-noise ratios (CNR) for ultrasonic images, receiver operating characteristic (ROC) analysis with corresponding indicators, the analysis of lesion area fitting relationships, and computational time consumption comparison. The mean CNR of hNSE imaging was 10.98 ± 4.48 dB, significantly surpassing the 3.82 ± 1.40 dB (p < 0.001, statistically significant) of Nakagami imaging and the 2.45 ± 0.74 dB (p < 0.001, statistically significant) of DACI imaging. This substantial difference underscores that hNSE imaging offers the highest contrast resolution for lesion recognition. Furthermore, we evaluated the ability of multiple ultrasonic parametric imaging to detect thermal ablation lesions using ROC curves. The area under the curve (AUC) for hNSE was 0.874, exceeding the values of 0.848 for Nakagami imaging and 0.832 for DACI imaging. Additionally, hNSE imaging exhibited the strongest linear correlation coefficient (R = 0.92) in the comparison of lesion area fitting, outperforming Nakagami imaging (R = 0.87) and DACI imaging (R = 0.85). hNSE imaging also performs best in real-time monitoring with each frame taking 6.38 s among multiple ultrasonic parametric imaging. Our findings unequivocally demonstrate that hNSE imaging excels in monitoring HIFU ablation treatment and holds the greatest potential for further clinical exploration.


Subject(s)
High-Intensity Focused Ultrasound Ablation , Ultrasonics , Liver/diagnostic imaging , High-Intensity Focused Ultrasound Ablation/methods , Ultrasonography/methods
13.
Chemosphere ; 354: 141676, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38462187

ABSTRACT

The existence of pollutants, such as toxic organic dye chemicals, in water and wastewater raises concerns as they are inadequately eliminated through conventional water and wastewater treatment methods, including physicochemical and biological processes. Ultrasonic treatment has emerged as an advanced treatment process that has been widely applied to the decomposition of recalcitrant organic contaminants. Ultrasonic treatment has several advantages, including easy operation, sustainability, non-secondary pollutant production, and saving energy. This review examines the elimination of dye chemicals and categorizes them into cationic and anionic dyes based on the existing literature. The objectives include (i) analyzing the primary factors (water quality and ultrasonic conditions) that influence the sonodegradation of dye chemicals and their byproducts during ultrasonication, (ii) assessing the impact of the different sonocatalysts and combined systems (with ozone and ultraviolet) on sonodegradation, and (iii) exploring the characteristics-based removal mechanisms of dyes. In addition, this review proposes areas for future research on ultrasonic treatment of dye chemicals in water and wastewater.


Subject(s)
Environmental Pollutants , Ozone , Water Pollutants, Chemical , Water Purification , Wastewater , Coloring Agents/chemistry , Ultrasonics , Water Pollutants, Chemical/chemistry , Water Purification/methods
14.
J Environ Manage ; 356: 120589, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38531126

ABSTRACT

The leaching of dissolved organic matter (DOM) from the sludge into the liquid phase is induced by ultrasound. However, there is limited investigation into the structure and molecular composition of sludge DOM in this process. The molecular structure and composition of sludge DOM in ultrasonic treatment were comprehensively elucidated in this study. The sludge dissolved organic carbon (DOC) and three-dimensional fluorescence spectroscopy (3D-EEM) image had most significant change at 15-min ultrasonic time and 1.2 W/mL ultrasonic density, respectively. Gas Chromatography-Mass Spectrometry (GC-MS) analysis indicated that ultrasonic treatment of sludge reduced the macromolecules to small molecules in DOM. Then, electrospray ionization Fourier-transform ion cyclotron resonance mass spectrometry (ESI FT-ICR-MS) analysis revealed that lignin, tannins, and carbohydrates were the main components of sludge DOMs after ultrasound treatment. analysis revealed that lignin, tannins, and carbohydrates were the main components of sludge DOMs after ultrasound treatment. Furthermore, through the Van Krevelen analysis, the major components were CHO (48.50%) and CHOS (23.20%) in the DOM of ultrasonicated sludge. This research provides the basis for the practical application of ultrasonic treatment of sludge and provides basic information for DOM components.


Subject(s)
Dissolved Organic Matter , Sewage , Lignin , Tannins , Ultrasonics , Carbohydrates
15.
JASA Express Lett ; 4(3)2024 03 01.
Article in English | MEDLINE | ID: mdl-38467469

ABSTRACT

Echolocating big brown bats (Eptesicus fuscus) broadcast downward frequency-modulated sweeps covering the ultrasonic range from 100-23 kHz in two harmonics. They perceive target range from the time delay between each broadcast and its returning echo. Previous experiments indicated that the bat's discrimination acuity for broadcast-echo delay declines when the lowest frequencies (23-35 kHz) in the first harmonic of an echo are removed. This experiment examined whether echo detection is similarly impaired. Results show that detection thresholds for echoes missing these lowest frequencies are raised. Increased thresholds for echoes differing in spectra facilitates the bat's ability to discriminate against clutter.


Subject(s)
Chiroptera , Echolocation , Animals , Ultrasonics , Behavior Therapy , Speech Disorders
16.
Int J Biol Macromol ; 264(Pt 1): 130526, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38431008

ABSTRACT

Although a promising method for lignin depolymerization, photocatalysis faces the challenge of low efficiency. In this study, MoS2/ZnO heterojunction catalysts, endowed with piezocatalysis and photocatalytic capabilities, were crafted through Zn ion intercalation for the depolymerization of phenoxyphenylethanol (PP-ol) and alkali lignin. Then, the synergistic interplay between ultrasonic-induced piezoelectric fields and heterojunctions was analyzed. The amalgamation of the piezoelectric field and heterojunction in MoS2/ZnO catalysts resulted in a diminished photogenerated hole/electron recombination efficiency, thereby fostering the generation of ·OH during the reaction. This pivotal role of ·OH emerged as a crucial reactive substance, converting 95.8 % of PP-ol through ß-O-4 bond breaking within a 3-h treatment. By incorporating ultrasonic, the contact probability of PP-ol with the catalyst was significantly improved, resulting in efficient conversion even with a reduced amount of acetonitrile in the solvent system (20 %). Furthermore, ultrasonic-light methods show high efficiency for depolymerizing Alkali lignin (AL), with 33.2 % of lignin undergoing depolymerization in a 4-h treatment. This treatment simultaneously reduces the molecular weight of AL and cleaves numerous chemical bonds within it. Overall, this work presents a green approach to lignin depolymerization, providing insights into the synergistic action of ultrasonic and photocatalysis.


Subject(s)
Lignin , Zinc Oxide , Lignin/chemistry , Ultrasonics , Molybdenum , Catalysis , Alkalies
17.
Neurosurg Rev ; 47(1): 117, 2024 Mar 16.
Article in English | MEDLINE | ID: mdl-38491331

ABSTRACT

An important step in the performance of endoscopic resection of colloid cysts of the third ventricle is the forced aspiration of cyst contents. The different consistencies these cysts may have can limit their complete resection and increase the likelihood of complications. The introduction of the ultrasonic neuroendoscopic aspirator allows cysts to be emptied more easily than with a conventional rigid aspirator, improving the feasibility of resection even in more solid cysts. The ability to regulate ultrasound and aspiration increases safety in a reduced and highly morbid space such as the third ventricle. Our objective was to determine the safety and efficiency of the ultrasonic aspirator for endoscopic resection of colloid cysts of the third ventricle. This was a retrospective descriptive study of patients with colloid cysts of the third ventricle undergoing neuroendoscopic resection using an ultrasonic aspirator between 2016-2023. Clinical, radiological, and procedural variables were studied. Mean, median and range were analyzed for quantitative variables and percentages and frequencies for qualitative variables. We present a series of 11 patients with colloid cysts of the third ventricle. The mean age was 44 years (27-69). All had biventricular hydrocephalus, with a mean cyst diameter of 15 mm (9-20). The lateral ventricle was accessed using the transforaminal approach in seven patients and the transchoroidal approach in three patients. All patients underwent septostomy. The mean endoscopy time was 40 min (29-68). Complete resection was possible in 10 patients. Median follow-up was 16 months (1-65) with 100% clinical improvement. At the end of follow-up, no patient had recurrence of the lesion. Based on our experience, the ultrasonic aspirator can be used safely and effectively for the resection of colloid cysts of the third ventricle, achieving high rates of complete resection with minimal postoperative complications.


Subject(s)
Colloid Cysts , Neuroendoscopy , Third Ventricle , Humans , Adult , Colloid Cysts/surgery , Third Ventricle/surgery , Third Ventricle/pathology , Retrospective Studies , Ultrasonics
18.
Meat Sci ; 212: 109465, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38452565

ABSTRACT

To study the impact of ultrasonic duration (0, 30, and 60 min) and sodium bicarbonate concentration (0% and 0.2%) on the gel properties of reduced-salt pork myofibrillar protein, the changes in cooking yield, colour, water retention, texture properties, and dynamic rheology were investigated. The findings revealed that added sodium bicarbonate significantly increased (P < 0.05) cooking yield, hardness, springiness, and strength of myofibrillar protein while reducing centrifugal loss. Furthermore, the incorporation of sodium bicarbonate led to a significant decrease in L⁎, a⁎, b⁎, and white values of cooked myofibrillar protein; these effects were further amplified with increasing ultrasonic duration (P < 0.05). Additionally, storage modulus (G') significantly increased for myofibrillar protein treated with ultrasonic-assisted sodium bicarbonate treatment resulting in a more compact gel structure post-cooking. In summary, the results demonstrated that ultrasonic-assisted sodium bicarbonate treatment could enhance the tightness of reduced-salt myofibrillar protein gel structure while improving the water retention and texture properties.


Subject(s)
Pork Meat , Red Meat , Animals , Swine , Sodium Bicarbonate , Ultrasonics , Red Meat/analysis , Sodium Chloride , Sodium Chloride, Dietary , Rheology , Water/chemistry
19.
eNeuro ; 11(4)2024 Apr.
Article in English | MEDLINE | ID: mdl-38514192

ABSTRACT

The inferior colliculus (IC), the midbrain auditory integration center, analyzes information about social vocalizations and provides substrates for higher level processing of vocal signals. We used multichannel recordings to characterize and localize responses to social vocalizations and synthetic stimuli within the IC of female and male mice, both urethane anesthetized and unanesthetized. We compared responses to ultrasonic vocalizations (USVs) with other vocalizations in the mouse repertoire and related vocal responses to frequency tuning, IC subdivisions, and sex. Responses to lower frequency, broadband social vocalizations were widespread in IC, well represented throughout the tonotopic axis, across subdivisions, and in both sexes. Responses to USVs were much more limited. Although we observed some differences in tonal and vocal responses by sex and subdivision, representations of vocal responses by sex and subdivision were largely the same. For most units, responses to vocal signals occurred only when frequency response areas overlapped with spectra of the vocal signals. Since tuning to frequencies contained within the highest frequency USVs is limited (<15% of IC units), responses to these vocalizations are correspondingly limited (<5% of sound-responsive units). These results highlight a paradox of USV processing in some rodents: although USVs are the most abundant social vocalization, their representation and the representation of corresponding frequencies are less than lower frequency social vocalizations. We interpret this paradox in light of observations suggesting that USVs with lower frequency elements (<50 kHz) are associated with increased emotional intensity and engage a larger population of neurons in the mouse auditory system.


Subject(s)
Inferior Colliculi , Mice , Female , Male , Animals , Inferior Colliculi/physiology , Ultrasonics , Vocalization, Animal/physiology , Sound , Mesencephalon
20.
Sci Rep ; 14(1): 6601, 2024 03 19.
Article in English | MEDLINE | ID: mdl-38503814

ABSTRACT

Tooth wear and pain are the primary concerns of patients undergoing periodontal scaling. The aims of this study were to compare the effects of a new magnetostrictive ultrasonic scaler and a traditional piezoelectric ultrasonic scaler on tooth surface roughness and calculus removal and to determine their impacts on patient discomfort during supragingival cleaning. This article had two parts: an in vitro study and a clinical study. In the in vitro study, thirty teeth with subgingival calculus were randomly assigned to two scaling treatment groups: magnetostrictive scalers (n = 15) and piezoelectric scalers (n = 15). Surface roughness measurements were taken at baseline and after scaling, and the root samples were visualised by SEM after scaling. Additionally, a single-centre randomised split-mouth clinical trial was conducted. Eighty-five participants diagnosed with chronic gingivitis or periodontitis were randomly assigned to receive supragingival scaling. The magnetostrictive scaler was used in half of the mouths (n = 85), and the piezoelectric scaler was used in the other half of the mouths (n = 85). Data on pain, noise, and vibration were collected using a VAS questionnaire, and the operating time was recorded. In both in vitro and clinical studies, magnetostrictive scalers were reported to be more effective than piezoelectric scalers in removing dental deposits (P < 0.05). Additionally, the root surface after scaling with the magnetostrictive scaler was smoother than that after scaling with the piezoelectric scaler in the in vitro study (P = 0.02). SEM examination also revealed that fewer dental materials were lost after instrumentation with the magnetostrictive scaler than after instrumentation with the piezoelectric scaler. Piezoelectric scalers caused less discomfort to patients in terms of pain, noise, and vibration than magnetostrictive scalers (P < 0.05). According to this clinical study, the magnetostrictive scaler caused more discomfort during supragingival scaling than the piezoelectric scaler. Moreover, the magnetostrictive scaler was also more efficient and produced a smoother root surface with less material loss after scaling than the piezoelectric scaler, as demonstrated in the in vitro study.


Subject(s)
Calculi , Tooth , Ultrasonic Therapy , Humans , Ultrasonics , Tooth Root , Pain
SELECTION OF CITATIONS
SEARCH DETAIL
...